Firmware · 2024-01
Uniden SDS100 firmware 1.03.03 sub (Motorola Type II test)
Verified — manufacturer file
Download zip (123 KB) Manufacturer's page ↗
Test sub firmware 1.03.03, issued by Uniden in January 2024 while investigating poor Motorola Type II reception after the Waterfall release. Per Uniden's readme it changes the 4FSK filter to a least-squares method. Superseded by public sub 1.03.05 (19 January 2024).
Read before installing. TEST BUILD - superseded. Not compatible with main 1.21.00 or older. Sentinel cannot overwrite it (its number is higher than the version on Uniden's server); return to sub 1.03.02 with the included file by the same manual method. Uniden has since hidden the link on its change-log page; the file is still served.
Contents
| File | Size | SHA-256 |
|---|---|---|
| SDS100 Motorola Type2 test Sub V1.03.03.zip | 120 KB | 90d5d89506b763c87949ca8db1086b6aa35f4ec3c94c43355999e4abaf79f814 |
| README.txt | These instructions | |
| SHA256SUMS | Checksums of the files above | |
Instructions
The complete README.txt included in the zip:
Uniden SDS100 firmware 1.03.03 sub (Motorola Type II test)
==========================================================
WHAT THIS IS
Test sub firmware 1.03.03, issued by Uniden in January 2024 while
investigating poor Motorola Type II reception after the Waterfall release. Per
Uniden's readme it changes the 4FSK filter to a least-squares method.
Superseded by public sub 1.03.05 (19 January 2024).
IMPORTANT: TEST BUILD - superseded. Not compatible with main 1.21.00 or older.
Sentinel cannot overwrite it (its number is higher than the version on
Uniden's server); return to sub 1.03.02 with the included file by the same
manual method. Uniden has since hidden the link on its change-log page; the
file is still served.
This is a TEST build that Uniden distributed during a fault investigation. It
is kept for the record; a scanner should run the current public release.
APPLIES TO
The Uniden SDS100 (US model) only. Every firmware file carries the model name
(SDS-100_...). Do not use it on the SDS200, SDS150, BCD436HP or BCD536HP. The
European SDS100E uses separately named firmware files (e.g.
SDS100E_V1_23_09.bin, per RadioReference owners) and must not be given these
files.
BEFORE STARTING
- A Windows PC. Uniden's instructions use Windows Explorer; the scanner
appears as an ordinary removable disk.
- The mini-USB data cable, in the mini-USB port on the side of the scanner
(the one marked Charge, not the micro-USB port).
- A fully charged battery (Uniden's readme asks for this), or the scanner on
USB charge.
- A backup: copy the whole microSD card to the PC and save the Favorites
Lists in Sentinel first (Uniden's readme asks for both).
- Main firmware newer than 1.21.00 (Uniden: the test sub is not compatible
with main 1.21.00 or older).
CONTENTS OF THIS ZIP
The download zip holds the vendor file exactly as Uniden published it, plus
this README.txt and SHA256SUMS.
SDS100 Motorola Type2 test Sub V1.03.03.zip (122701 bytes)
SHA-256 90d5d89506b763c87949ca8db1086b6aa35f4ec3c94c43355999e4abaf79f814
Inside SDS100 Motorola Type2 test Sub V1.03.03.zip:
Readme SDS100 Sub Motorola type 2 test V1_03_03.txt
Uniden's own instructions
2782 bytes
SHA-256 5303156bf013112af3844114e2479dcce374ccd14b95117cbcb98bb9079de896
SDS-100-SUB_V1_03_02.firm
public sub-processor firmware 1.03.02, for going back
88816 bytes
SHA-256 01cc450f9633c33e3c3a99a19c33adac1f570b983431af9304a7fc9a02930dcf
SDS-100-SUB_V1_03_03.firm
test sub-processor firmware 1.03.03
88864 bytes
SHA-256 71fa59340f64d8f742f92c6f34b7b208a7735f66c666fd6a6225d9fa226e273c
INSTALLATION
1. Turn the scanner on.
2. Connect it to the PC with the USB cable. The scanner shows "USB Cable
Detected / Select USB mode" with "Mass Storage = E" and "Serial Port =
.".
3. Press E (Yes) to choose Mass Storage. The scanner shows "USB Mass
Storage".
4. In Windows Explorer, open the new removable disk, then the "BCDx36HP"
folder, then its "firmware" folder. It already holds CitiTable_V00_00.dat
and ZipTable_V00_00.dat - do not touch or delete them.
5. Unzip the download on the PC and copy the test sub file
SDS-100-SUB_V1_03_03.firm into the "firmware" folder. Only one main
(.bin) and one sub (.firm) file may be in the folder at a time; with
several versions present the update will not start or will load
incorrectly.
6. Restart the scanner ("reset the power", in Uniden's words). The update
starts automatically as it boots. Do not turn the scanner off until the
update has finished.
7. When it has finished, the scanner deletes the firmware file(s) from the
"firmware" folder by itself.
VERIFYING
Menu -> Settings -> See Scanner Information -> Firmware Version shows the main
and sub versions now installed. The firmware file(s) will also have gone from
the card's "firmware" folder.
IF SOMETHING GOES WRONG
- Update did not start: check that only one main and one sub file are in the
"firmware" folder and that the file names are exactly as supplied.
- Scanner will not start properly after files were deleted from the
"firmware" folder: the two .dat files were probably removed. Uniden's
remedy is Sentinel -> Clear User Data, which rebuilds the card but erases
all user data (hence the backup).
- USB connection fails or is slow: take the microSD card out and use a card
reader; Sentinel can work on the card directly (see Vol 5 on this site).
The same folder layout applies.
- Card errors: back up what is readable, format the card with the SD
Association's SD Memory Card Formatter (cards up to 32 GB), run Sentinel
-> Clear User Data, then Update Firmware.
- Uniden does not document a recovery procedure for an update interrupted by
power loss; this could not be confirmed from any source. Uniden's readme
closes with "Please use these files on your risk."
DOWNGRADING
Uniden's readme: Sentinel cannot overwrite this test version because its
number is higher than the version on Uniden's server. To go back, copy the
public files included in this package the same way. A later public release
(sub 1.03.05 or newer, installed by Sentinel) also replaces it.
PROVENANCE
- Official source:
https://info.uniden.com/twiki/pub/UnidenMan4/SDS100FirmwareUpdate/SDS100%20Motorola%20Type2%20test%20Sub%20V1.03.03.zip
- Listed on:
https://info.uniden.com/twiki/bin/view/UnidenMan4/SDS100FirmwareUpdate
- Wayback copy: none captured
- Retrieved: 2026-09-18. Status: verified (downloaded from Uniden's own
server).
MORE INFORMATION
- scanners.fubsypoly.com, Uniden SDS100 - Vol 5, Upgrades & Firmware:
https://scanners.fubsypoly.com/uniden-sds100/vol-5/
- Reference Library, SDS100 Owner's Manual:
https://scanners.fubsypoly.com/library/uniden-sds100-original-manual/
- Reference Library, Easier to Read SDS100/SDS200 Manual:
https://scanners.fubsypoly.com/library/easier-to-read-sds100-200-manual/
- Uniden change log:
https://info.uniden.com/twiki/bin/view/UnidenMan4/SDS100FirmwareUpdate
- RadioReference thread on the Motorola Type II test builds:
https://forums.radioreference.com/threads/sds-100-200-motorola-type-ii-public-beta.467806/
Other versions of SDS100 firmware
- 1.26.01 main / 1.03.15 sub · 2026-03-27Recommended
- 1.23.20 main · 2025-10-17
- 1.23.15 main / 1.03.06 sub · 2025-03-24
- 1.23.07 main · 2024-03-22
- 1.03.05 sub · 2024-01-19
- 1.03.04 sub / 1.23.03A main (Motorola Type II test) · 2024-01-12
- 1.23.02 main / 1.03.02 sub · 2023-12
- 1.21.00 main / 1.02.01 sub · 2022-06-29
- 1.06.00 main / 1.01.05 sub (public beta) · 2018-09-28
- 1.05.01 main / 1.01.05 sub (public beta) · 2018-08
- 1.05.00 main / 1.01.05 sub (open beta) · 2018-07-27
- 1.04.01 main / 1.01.05 sub (open beta) · 2018-07-17
- 1.02.05b main (open beta) · 2018-06-22