Firmware · 2024-03-22
Uniden SDS100 firmware 1.23.07 main
Verified — manufacturer file
Download zip (2.1 MB) Manufacturer's page ↗
Main firmware 1.23.07 (22 March 2024). It fixed the P25 Phase 2 NAC not being displayed correctly on voice channels.
Read before installing. Posted by Uniden for stepping back from main 1.23.15 to 1.23.07. The package contains no sub firmware.
Contents
| File | Size | SHA-256 |
|---|---|---|
| SDS100_V1.23.07_Main.zip | 2.1 MB | d1ca286b77f7f70584a67857ef3bab4edb4984c1b289bfbab24a6b4dee194014 |
| README.txt | These instructions | |
| SHA256SUMS | Checksums of the files above | |
Instructions
The complete README.txt included in the zip:
Uniden SDS100 firmware 1.23.07 main
===================================
WHAT THIS IS
Main firmware 1.23.07 (22 March 2024). It fixed the P25 Phase 2 NAC not being
displayed correctly on voice channels.
IMPORTANT: Posted by Uniden for stepping back from main 1.23.15 to 1.23.07.
The package contains no sub firmware.
Uniden normally delivers firmware only through Sentinel (UPDATE -> Update
Firmware), which always installs the newest version. Uniden published this
package on its change-log page so that owners can install this specific
version by hand - in practice, to go back to it. To bring a scanner up to
date, use Sentinel instead.
APPLIES TO
The Uniden SDS100 (US model) only. Every firmware file carries the model name
(SDS-100_...). Do not use it on the SDS200, SDS150, BCD436HP or BCD536HP. The
European SDS100E uses separately named firmware files (e.g.
SDS100E_V1_23_09.bin, per RadioReference owners) and must not be given these
files.
BEFORE STARTING
- A Windows PC. Uniden's instructions use Windows Explorer; the scanner
appears as an ordinary removable disk.
- The mini-USB data cable, in the mini-USB port on the side of the scanner
(the one marked Charge, not the micro-USB port).
- A fully charged battery (Uniden's readme asks for this), or the scanner on
USB charge.
- A backup: copy the whole microSD card to the PC and save the Favorites
Lists in Sentinel first (Uniden's readme asks for both).
CONTENTS OF THIS ZIP
The download zip holds the vendor file exactly as Uniden published it, plus
this README.txt and SHA256SUMS.
SDS100_V1.23.07_Main.zip (2164639 bytes)
SHA-256 d1ca286b77f7f70584a67857ef3bab4edb4984c1b289bfbab24a6b4dee194014
Inside SDS100_V1.23.07_Main.zip:
Readme SDS100 V1_23_07.txt
Uniden's own instructions (downgrade from main 1.23.15)
2176 bytes
SHA-256 b9e1c580c9b7646be0dac5ac9da72304ec93551b3afadcbe70eaef5ba798f88a
SDS-100_V1_23_07.bin
main (CPU) firmware 1.23.07
2162688 bytes
SHA-256 813e64f756a89de91d25c952957a0af8d41f2fbb5ca7e247233ebf23b60cf3fa
INSTALLATION
1. Turn the scanner on.
2. Connect it to the PC with the USB cable. The scanner shows "USB Cable
Detected / Select USB mode" with "Mass Storage = E" and "Serial Port =
.".
3. Press E (Yes) to choose Mass Storage. The scanner shows "USB Mass
Storage".
4. In Windows Explorer, open the new removable disk, then the "BCDx36HP"
folder, then its "firmware" folder. It already holds CitiTable_V00_00.dat
and ZipTable_V00_00.dat - do not touch or delete them.
5. Unzip the download on the PC and copy SDS-100_V1_23_07.bin into the
"firmware" folder. Only one main (.bin) and one sub (.firm) file may be
in the folder at a time; with several versions present the update will
not start or will load incorrectly.
6. Restart the scanner ("reset the power", in Uniden's words). The update
starts automatically as it boots. Do not turn the scanner off until the
update has finished.
7. When it has finished, the scanner deletes the firmware file(s) from the
"firmware" folder by itself.
VERIFYING
Menu -> Settings -> See Scanner Information -> Firmware Version shows the main
and sub versions now installed. The firmware file(s) will also have gone from
the card's "firmware" folder.
IF SOMETHING GOES WRONG
- Update did not start: check that only one main and one sub file are in the
"firmware" folder and that the file names are exactly as supplied.
- Scanner will not start properly after files were deleted from the
"firmware" folder: the two .dat files were probably removed. Uniden's
remedy is Sentinel -> Clear User Data, which rebuilds the card but erases
all user data (hence the backup).
- USB connection fails or is slow: take the microSD card out and use a card
reader; Sentinel can work on the card directly (see Vol 5 on this site).
The same folder layout applies.
- Card errors: back up what is readable, format the card with the SD
Association's SD Memory Card Formatter (cards up to 32 GB), run Sentinel
-> Clear User Data, then Update Firmware.
- Uniden does not document a recovery procedure for an update interrupted by
power loss; this could not be confirmed from any source. Uniden's readme
closes with "Please use these files on your risk."
DOWNGRADING
This package exists for going back: Uniden's readme covers moving from main
1.23.15. To return to the current version afterwards, run Sentinel -> UPDATE
-> Update Firmware.
PROVENANCE
- Official source:
https://info.uniden.com/twiki/pub/UnidenMan4/SDS100FirmwareUpdate/SDS100_V1.23.07_Main.zip
- Listed on:
https://info.uniden.com/twiki/bin/view/UnidenMan4/SDS100FirmwareUpdate
- Wayback copy:
https://web.archive.org/web/20260101191212/https://info.uniden.com/twiki/pub/UnidenMan4/SDS100FirmwareUpdate/SDS100_V1.23.07_Main.zip
- Retrieved: 2026-09-18. Status: verified (downloaded from Uniden's own
server; SHA-1 matches the Wayback capture).
MORE INFORMATION
- scanners.fubsypoly.com, Uniden SDS100 - Vol 5, Upgrades & Firmware:
https://scanners.fubsypoly.com/uniden-sds100/vol-5/
- Reference Library, SDS100 Owner's Manual:
https://scanners.fubsypoly.com/library/uniden-sds100-original-manual/
- Reference Library, Easier to Read SDS100/SDS200 Manual:
https://scanners.fubsypoly.com/library/easier-to-read-sds100-200-manual/
- Uniden change log:
https://info.uniden.com/twiki/bin/view/UnidenMan4/SDS100FirmwareUpdate
Other versions of SDS100 firmware
- 1.26.01 main / 1.03.15 sub · 2026-03-27Recommended
- 1.23.20 main · 2025-10-17
- 1.23.15 main / 1.03.06 sub · 2025-03-24
- 1.03.05 sub · 2024-01-19
- 1.03.04 sub / 1.23.03A main (Motorola Type II test) · 2024-01-12
- 1.03.03 sub (Motorola Type II test) · 2024-01
- 1.23.02 main / 1.03.02 sub · 2023-12
- 1.21.00 main / 1.02.01 sub · 2022-06-29
- 1.06.00 main / 1.01.05 sub (public beta) · 2018-09-28
- 1.05.01 main / 1.01.05 sub (public beta) · 2018-08
- 1.05.00 main / 1.01.05 sub (open beta) · 2018-07-27
- 1.04.01 main / 1.01.05 sub (open beta) · 2018-07-17
- 1.02.05b main (open beta) · 2018-06-22
- 1.02.05a main (open beta) · 2018-06-15