Whistler WS1080/WS1088 EZ Scan Digital Handheld Scanner — Owner's Manual (Part 1)
Untitled-1 1
WS1080/WS1088
User Guide
EZ SCAN DIGITAL
HANDHELD
RADIO
SCANNER
jiasd Ww)
jeather Radio SKYWARN
ed
WHISTLER
® |
2015-11-10 9:55:52
Untitled-1 2
®
INtrODUCTION.. ces cececeecceesesesesesesenensesesesesesenseseseseseenenseserea 4
What is Object Oriented Scanning?...........cce eee 4
FO atures... cece cece eeeeeseseseeeeesessesstsessieeseneesieeeeeeeees 5
Package Content.......:.cccccceeesesetetetseseseaeetetensrsesenenens 5
Scanning Legally... eens eeereeeeseeseensneeereees 6
FCC Statement.....cccccccccceceeecsessenessensnsentisesesreets 7
SOtUD eee ccceccceceeeeeseensesensesensesensesenscsecsesensesenesieeseeeneeseneets 8
Antenna.......eceeeeeeeee 8
Headphones and Speakers... AD
Batteries... eee 10
External POWe? occ cceceeceee ees eseeneesceeeeereentesneneees 11
Swivel Belt Clip... ccc cece cesses eeesneistceeeeseeeees 11
Understanding the Keypad... cece eens 12
Turning On and Set Squelch.....cceeeeetenees 13
Set Bandplan and Clock.....cccccccccceeseetetetetetseeeees 14
Program Methods.........ccccccceeeeeeeteseeesereseeenetees 15
Setting Location... ccc eeceeeereeettsereteteteerneees 16
Power Up Password.......ccccccccccccsessesetetsesesessstetsnsesesesees 18
Understanding the Display.
psDr Indicators... 20
Display Icons....... 21
EZ Scan Library... 22
Maximum Card Size............ 23
Installing EZ Scan Software... ccc ceeeeteeeees 24
Library Updates... iccceeeeseceteeseseseteesesesereseseeees 24
PreferredProgrammingfrom Library........0cccceee 25
Backup into the first V-Scanner folder... 26
Updating the Library (EZ Scan)... cece 26
Library Structure... eccccceceseseeetecseetstsesesetseensnsesesenees 27
EZ Scan Library Notes........ccccccccccecseceteeseseeetetetenseseseaees 27
Manual Programming Conventional Frequency........... 27
Standard Text Entry Method... eee 28
Creating Your First New Objects.............. 30
Essential Conventional Channel Parameters... .30
Essential Trunking Talkgroup Parameters.........0..... 31
Setting up a Trunking System (TSYS) Object............. 31
Adding a New Trunking System (TSYS).........:eee 32
Adding the first Talkgroup.......c.ceceeeeeeerere erent 33
Talkgroup Object (TGRP).......:cc eee ceeeree eerste 35
Editing Objects Manually... cccceececesseseeeseeeees 36
Alert LED Setting... eteneieeeereeesneesneeees 38
Recording/Playback..........ccccccceeeeeeseeesetseeseseees 43
IF QUtOU EL. cee eeceeeecscseetseneessesessisieessssesenees 44
2
2015-11-10
9:55:58
Untitled-1 3
®
Internal Clock/Calendat....c.ccccccccccseesesetetetetsesesesenens 45
Scanning Monitoring and Scanning...........eeee 45
Frequency or TalkQroups......c.ccceceeseseesetseeeeseseeeeneeees 45
Active Scanlists.....0.0.cccccccccccsesesetecseseseseseenecseseseseseenets 45
Enable/ Disable Scanlists.........0.0cccccceseceseseeeeeseeeeens 46
Lock Out Objects... cece eeeeeteeseseseteseeseseseseeeeees 46
Skip Transmission ....cccccccccscscsceceseeeetetetseseseseeteteneeseees 46
Rename Scanlists...... 47
Set Priority Objects...... 47
Scanlists and Scan Sets 47
Searching. ....cccscececcece esses es ese esesesiseeseseeesiseesesseereteesets 48
Using Spectrum SWeepel........ cece eeeeeseeeeeseseseteees 48
Perform a Service Search .......c.ceccecsecesesseeeteseseseeeeeenenenes 49
Perform a Limit Search.......ccccceceeeceseetsseteeeeseeeenenenes 49
To Save Found Frequencies.......cccccccccsccseeeeeseseteneees 49
Search Settings... ccc eee eeeeceeeeseesesesieeseeseeeees 50
Spectrum Sweeper Settings... eee eeeereeee 50
Service Search Settings.........ececececcceseereseeseeneteteeeees 50
Limit Search Settings... cee 90
Saving Found CTCSS or DCS Codes..... 51
Weather Monitoring.........ccceeeee 52
Program FIPS Codes.
Entering SAME Location and Event Codes... 53
SAME Standby Mode’...........:ccccecseeeeeeeeeneeeeeeeeeees 54
Weather Priority......0...ccccececeeeeecceseseseeeteseseseseseestteneets 55
SKYWARNG 0.0. cccecccece eee ee cence eseseseseseensesenentiteseteeeeens 55
Using V-Scanner Storage.........cccecceeeeeeeeeeeeeeeetees 56
Configuring SettingS......0..ccecce cee esneeneteesieeeneeeees 56
Using EZ Scan Software to Update Scanner........... 59
DSP Firmware Updates.........cccccccceeesesetetetsesesesesenens 59
Updating the Library (PC)... cece eeeeeeeeees 59
Maintenance .......... 60
Birdie Frequencies..........:cccccceeee 60
Troubleshooting/Error Messages..... 61
Library Copyright Notice... cece ries 64
SPeCifications oo. cccececccccccce ees eeetecsestsesesesetetstsssesesesees 65
Frequency Coverage........cccccccecceeseeseisiseeeeeseees 66
Consumer Warranty. ......ccccccccececereeseseteeseseeeteseneneees 67
Service Under Warranty...........:ccccseceseeeeeeeeeeieeeees 68
Service Out of Warranty... ccccccceseseeeseeeteteteteeeees 69
3
2015-11-10
9:55:59
| e |
Introduction
Scanning technology has changed dramatically over
the years. The WS1080 / WS1088 scanner with Object
Oriented User Interface is designed to help the
hobbyist build a collection of channels to scan:
e Start small and expand
¢ Organize channels and talkgroups
e Remove unwanted channels and talkgroups
What is Object Oriented Scanning?
Programming scanning receivers can be challenging,
but object-oriented programming simplifies the process
by using common conventions for scanning concepts
that have common characteristics.
A Scannable Object is any defined item that can be
@ scanned or monitored, including: @
® Conventional, non-trunked radio frequencies
e Talkgroups used on a trunked radio system
e Radio services
¢ Defined searches
Because scannable objects are defined by the same
basic elements, the Object Oriented User Interface
(OOUI) is designed to simplify scanning by managing
all scannable objects similarly. When you learn how to
program one type of object, you can program other
types of scannable objects as well.
Untitled-1 4 2015-11-10 9:55:59
®
Features
Functional keypad and backlit LCD display
USA/Canada Radio Reference database on SD Card
Quick Location based Programming (City, Zip,
County)
Detects and masks encrypted voice audio
Decodes Radio ID/Talkgroup ID data
Upgradeable CPU Firmware, DSP Firmware and
Database Library
USB Interface 2.0 or earlier
Improved P25 Functionality (Phase II, X2-TDMA)
PC Software to customize your settings
Signal Strength Meter
200 Scanlists
Weather Radio Functions
Multi-system Trunking
Spectrum Sweeper
Headphone Jack
Programmable Alert LED
Programmable Audio Alarms
V-Scanner II Storage System
Audio Recording
Built-in Clock/Calendar
Built-in Services Searches
Built-in Discriminator output
Package Contents
Handheld Scanner
Antenna
USB Cable
Micro SD Card (Installed in the Scanner)
PC Software included on SD Card
Swivel Belt Clip
User Guide
Quick Start Guide
Untitled-1 5
2015-11-10
9:55:59
Untitled-1 6
®
Scanning Legally
Your scanner covers frequencies used by many
different groups including police and fire departments,
ambulance services, government agencies, private
companies, amateur radio services, military operations,
pager services, and wireline (telephone and telegraph)
service providers. It is legal to listen to almost every
transmission your scanner can receive. However, there
are some transmissions you should never intentionally
listen to.
These include:
Telephone conversations (cellular, cordless, or other
means of private telephone signal transmission)
Paging transmissions
Any intentionally decoded scrambled or encrypted
transmissions
According to the Electronic Communications Privacy
Act (ECPA), you are subject to fines and possible
imprisonment for intentionally listening to, using, or
divulging the contents of such a transmission unless
you have the consent of a party to the communication
(unless such activity is otherwise illegal). This scanner
has been designed to prevent reception of illegal
transmissions. This is done to comply with the legal
requirement that scanners be manufactured so as to not
be easily modifiable to pick up those transmissions.
Do not open your scanner’s case to make any
modifications that could allow it to pick up
transmissions that are illegal to monitor. Doing so
could subject you to legal penalties. We encourage
responsible, legal scanner use. In some areas, mobile
use of this scanner is unlawful or requires a permit.
Check the laws in your area. It is also illegal in many
areas to interfere with the duties of public safety
officials by traveling to the scene of an incident without
authorization.
Even where not permitted, mobile use of a scanner is
typically permitted if you are a licensed Amateur Radio
operator capable of emergency radio communications.
If interested, see www.arrl.org for information on
becoming a ham radio operator.
2015-11-10
9:55:59
| e |
FCC Statement
This equipment has been tested and found to comply
with the limits for a scanning receiver, pursuant to
Part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful
interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio
communications. However, there is no guarantee that
interference will not occur in a particular installation.
If this equipment does cause harmful interference to
radio or television reception, which can be determined
by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or
more of the following measures:
e Reorient or relocate the receiving antenna.
e Increase the separation between the equipment and
receiver.
¢ Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected.
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1)This device may not cause harmful interference. (2)
This device must accept any interference received,
including interference that may cause undesired
operation.
WARNING: Changes or modifications to this unit
not expressly approved by the party responsible for
compliance could void the user's authority to operate
the equipment.
Shielded cables must be used with this unit to ensure
compliance with the Class B FCC limits.
Untitled-1 7 2015-11-10 9:56:00
| e |
Antenna
To connect the included antenna:
1. Align the slots around the
antenna’s connector with the tabs on
the antenna jack.
2. Press the antenna down over the
jack and turn the antenna’s base
clockwise until it locks into place.
You can use a variety of antennas. To
connect and external antenna, follow
the installation instructions supplied
with the antenna. Always use 50-ohm
coaxial cable, such as RG-58 or RG-8 low-loss dielectric
coaxial cable. You may also need a BNC adapter.
@ WARNING: Use extreme caution when installing or @
removing an outdoor antenna. If the antenna starts
to fall, let it go! It could contact overhead power
lines. If the antenna touches a power line, touching
the antenna, mast, cable, or guy wires can cause
electrocution and death. Call the power company
to remove the antenna. DO NOT attempt to do so
yourself.
N ae —— COAXIAL CABLE
LIGHTNING ARRESTOR
GROUNDING CONDUCTORS
(NEC SECTION 810-21)
2——=— GROUND CLAMPS
METER PANEL AND
SERVICE ENTRANCE —___ “Eg
oo
_. POWER SEAVICE GROUNDING
ELECTRODE SYSTEM
(NEC ART 250. PART H)
NEC «NATIONAL ELECTRICAL CODE
Untitled-1 8 2015-11-10 9:56:00
Untitled-1 9
®
WARNING: Outdoor antennas must be properly
grounded to prevent static buildup and lightning
damage. Article 810 of the National Electrical Code,
ANSI/NFPA 70, provides information about proper
grounding of the antenna mast, connection of coaxial
cable to an lightning arrestor, size of grounding
conductors, location of the lightning arrestor and
connection of grounding conductors to grounding
electrodes.
Disconnect your radio from the outdoor antenna during
electrical storm activity to prevent damage.
Headphones and Speakers
You can plug headphones (not supplied) or an amplified
speaker (not supplied) with a 1/8 inch (3.5mm) stereo
mini-plug in the headphone jack on top of your scanner.
This automatically disconnects the internal speaker.
NOTE: Use an amplified speaker; a non-amplified
speakers may not provide sufficient volume for
comfortable listening.
Listening Safely
To protect your hearing, follow these guidelines when
you use headphones:
Set the volume to zero before putting on headphones.
With the headphones on, adjust the volume to a
comfortable level.
Avoid increasing the volume after you set it. Over time,
your sensitivity to a volume level decreases, so volume
levels that do not cause discomfort might damage your
hearing. Avoid or limit listening at high-volume levels.
Prolonged exposure to high-volume levels can cause
permanent hearing loss.
Wearing headphones while operating a motor vehicle
or riding a bicycle can create a traffic hazard and is
illegal in most areas. Even though some headphones let
you hear some outside sounds when listening at normal
volume levels, they still can present a traffic hazard.
Exercise extreme caution!
2015-11-10
9:56:00
Untitled-1 10
®
A low battery warning sounds every 30 seconds (default
setting) when the batteries are ae
low.
1. Be sure to turn the scanner
off!
2. Slide open the battery
compartment cover.
Battery Type Selector
3. Set the Battery Type Selector:
e ALKA - Alkaline
e NI-MH — Rechargeable NI-MH
4. Install four AA batteries, matching the polarity
symbols (+ and -).
5. Replace the cover.
WARNING: Never install alkaline batteries with the
Battery Type Selector switch set to NI-MH. Alkaline
batteries can get hot or explode if you try to recharge
them.
Recycle Rechargeable Batteries
Recycle your old rechargeable batteries
at one of the many collection sites in
the U.S. and Canada. To find the site
nearest you, visit www.call2recycle.org
or call toll- free 1-877-2-RECYCLE.
Battery Notes:
Use only fresh batteries of the required size and type.
Do not mix old and new batteries, different battery
types (alkaline or rechargeable), or rechargeable
batteries of different capacities.
Dispose of batteries promptly and properly; do not
burn or bury them.
For long-term storage (a month or longer), remove the
batteries. Batteries can leak chemicals that can damage
electronic parts.
Do not overcharge rechargeable batteries.
Overcharging shortens battery life.
10
2015-11-10
9:56:01
Untitled-1 11
®
External Power
Always turn the scanner off before
connecting or disconnecting power
sources. Use the supplied USB cable
to connect the scanner to a USB power
source (not included).
Some USB power adapters can interfere
with the scanner's reception. Using an
incompatible USB cable may damage
your scanner.
NOTE: If your vehicle’s engine is
running, you might hear electrical noise
from the engine while scanning. This is
normal.
Swivel Belt Clip
Swivel clip allows the scanner to
move with you and easily move it
out of the way without unclipping it
from your belt. To attach the Swivel
clip to the scanner; align the belt clip
grooves to the slots on the back of
the scanner. Slide the clip down until
it clicks in place. To remove the belt
clip, pull back on the small tab and
slide the clip upward.
11
2015-11-10
9:56:01
Untitled-1 12
®
Understanding the Keypad
Your scanner features an easy-to understand backlit
keypad.
WS1080 WS 1088
POWER - press and hold (!) for one second to turn on
and off. Press briefly to confirm the backlight level
MENU - provides access to additional functions related
to the current operating mode of the scanner, and
provides access to the Main Menu where the main
functions are controlled.
WX - provides instant access to NOAA Weather Radio
broadcasts and SAME Weather Alert Receiver mode.
Press twice to select SCYWARN® Scanlist. (SKYWARN®
requires one-time programming)
ATT — controls the attenuator function and cycles
between per object attenuation mode, Global
attenuation mode, and Global attenuation on.
PRI — toggles the Priority setting for selected or active
object, Fn PRI toggles Priority Mode on or off while
scanning.
SKIP — if pressed while monitoring or paused on an
Object will temporarily disable reception on the Object.
Pressing SKIP again while the Object is selected will
resume normal monitoring. The SKIP key can also
be programmed to permanently lockout an object
if selected in the settings menu. When editing text,
pressing the SKIP key clears all text at and to the right
of the cursor. When in Playback mode, the SKIP key
stops playback of the current recording, and when
playing multiple recordings, advances to the next
recording. When in Weather mode, the SKIP key
toggles between Normal weather radio mode and
SAME Standby mode. In many Menu functions, the
SKIP key is used to cancel or abort a pending change.
Fn — activates alternate key functions.
12
®
2015-11-10
9:56:01
Untitled-1 13
®
P/II/SEL — controls the Scan, Pause, and Playback
modes, and is used in menus to select, enable, or
disable options.
Four Way Push button Pad —- AV, <4 P keys are used
for navigation while browsing objects and menus.
Alphanumeric Keypad (WS1088) — quick data entry of
frequencies, talkgroup ID’s and labels. While scanning,
pressing 1 thru 200 will toggle the selected scanlist on
or off. Each button must be pressed within 2 second
of the last. If more than 1 scanlist will be toggled on or
off, press the decimal once as a separator. Pressing the
decimal twice will end the sequence.
Example: If you wish to toggle scanlist 9 you press 9 If
you wish to toggle scanlist 9, 11, and 22 simply press
the following 9.11.22 0r9.11.22.0r9. 11. 22.
Turn on Scanner and Set Squelch
Preset squelch between 10 and 12 o'clock position.
While scanning, turn the knob down (counterclockwise)
until you hear noise then up (clockwise) a little past
where the noise stops. The higher the squelch is set, the
stronger the signal required to break the squelch.
Squelch
Power
Press and
hold to turn
ON/OFF.
Press
briefly to
toggle the
backlight.
13
2015-11-10
9:56:01
Untitled-1 14
®
Setting Bandplan and Clock
When you first power up your scanner it will prompt you
to set the bandplan, date and time.
Press the < or ® key to select the USA or Canada
bandplan, then press P/II/SEL.
-Bandplan- -Bandplan-
=] USA > a Canada ie
Press SEL to Set Press SEL to Set
The scanner will then prompt you to enter the current
date and time. Press the < or ® key to select the
desired digit, then press the A key. Press the < or ®
key to change the value, then press P/II/SEL. You can
skip this process by pressing the SKIP key. You can set
the clock at any time using the EZ Scan Software.
-Set Clock-
2014-06-03 Sat
11:00:25
Press SEL to Set or SKIP to Exit
The Bandplan and Date/Time prompts appear only
once on initial power-up. You can change the Date and
Time from the Main Menu and the Bandplan from the
Setting menu.
14
2015-11-10
9:56:02
Untitled-1
15
®
Program Methods
There are two methods to program your scanner.
To get started quickly, you can use “Set Location.”
The set location method stores objects in your area
automatically and puts them in Scanlists 151 and higher.
These Scanlists are already named, “Multi Dispatch,”
“Law Tac,” “Interop” “Fire Talk,” and so forth. This
method gets you scanning in minutes, but you cannot
monitor a single police or a single fire department —
they will all be together in the same Scanlist. Also, if
you use set location, and wish to add a new location, be
sure to “Clear Channels” to erase old objects before
storing the new location. If you store more than one
ZIP code, the scanner will spend a great deal of time
searching for objects that are out of range. That will
cause the scanner to miss some local transmissions you
want to hear.
Although it takes longer, experienced users will want to
program Scanlists on their own using the “Preferred”
method. Use “Browse Library” to select your state
and county and look for agencies of interest. Check the
boxes of objects you wish to import, select the Scanlist
you want to put them in and perform the import (see
Preferred Programming). Once you save objects to a
Scanlist, rename the Scanlist so you don’t forget what
you stored there. Then import more objects into a
different Scanlist and rename that one. In this way, you
can create Scanlists such as Bethel Police, Hurst Police,
Bethel Fire, Shenango EMS, etc. Individual scanlists
allow you to decide exactly what you want to scan.
15
2015-11-10
9:56:02
Untitled-1 16
®
Setting Location
Your scanner can select services to scan based on your
location. Press MENU and scroll to “Set Location” and
press the P key.
You can specify your location by City, County or ZIP
Code. Scroll to the desired method and press the >
key. If you select City or County, the scanner will prompt
you for your State. Use the AorW key to select the first
letter of your State, then press the P/II/SEL key. Scroll
to your state and press the ® key. Use the AorW key to
select the first letter of your City or county, then press
the P/II/SEL key. Scroll to your City or County, then
press the P key.
Select County:
First letter: A
SEL = Done
If you select ZIP Code, the scanner will prompt you to
enter your five-digit ZIP Code. Use the AorW key to
adjust each digit, then use the < or ® key to select
each digit. When you are done, press the P/II/SEL key.
ZIP Code
00000
<P) moves cursor
SEL=OK MENU=BACK
NOTE: Although you can program multiple locations, to
get maximum scanner performance its best to program
only 1 location or ZIP code. Scanning multiple locations
will cause missed transmissions due to the scanner
searching for out of range frequencies.
You can accept a preselected set of Default Types for
your location, or you can specify Custom Types (see
next section). To select the Default Service Types, press
the P key, then the P/II/SEL key to import the Default
Set of Service Types for that City or County. Wait for the
Import process to end, then press the P/II/SEL.
-Confirmation-
Really do import operation?
SEL=Yes SKIP=No
To perform additional imports, press the P/II/SEL key
and proceed as before. Press the SKIP key to return to
the Main Menu.
16
2015-11-10
9:56:02
®
To select Custom Types, press the P® key. Scroll
through the list of Services and press the P/II/SEL key
to select Services you wish to import. A check mark
appears next to each selected Service.
Services:
SEL = Toggle
Multi Dispatch
Law Dispatch O
Fire Dispatch O
EMS Dispatch O
When you are done, press the ® key, then the
P/ II/SEL key to import the selected services. Press the
SKIP key to return to the Service list without importing.
To perform additional imports, press the P/II/SEL key
and wait for import process to end. Press the SKIP key
to return to the Main Menu.
Services selected through Set Location are
automatically assigned to Scanlists beginning at number
151; each selected Service is assigned to a separate
& Scanlist, which is given the name of the service. &
These Scanlists are automatically selected for Scanning.
You can select or deselect Scanlists as desired through
the Scanlist item on the Main Menu.
NOTE: Press < or MENU to return to main menu.
To clear all data from the current Folder on the Set
Location menu scroll to Clear Channels and press the >
key. On the Confirmation screen press the P/II/SEL key
to clear the data, or press the SKIP key to return to the
Set Location menu without clearing.
-Confirmation-
Really clear ALL programmed data from the current
folder?
SEL=Yes, SKIP=No
NOTE: The Clear Channels function erases all of your
current scanning data; all Scanlists in this Folder will
be empty. Use this function carefully, as it cannot be
undone. Does not affect V-Scanner folders content.
17
Untitled-1 17 2015-11-10 9:56:02
Untitled-1 18
®
Power up Password
Set a user defined power-on password to restrict access
to the radio.
1. Press MENU.
2. Scroll to Set Password and press P.
3. Use the arrows to set the password.
4. Use the P/II/SEL key to accept the updated settings,
or the MENU key to exit without saving changes.
NOTE: Power-on password can be reset by anyone
using the EZ Scan software. Password provides only
limited protection from immediate unauthorized use.
Understanding the Display
Your scanner features a high contrast, backlit Liquid
Crystal Display (LCD) to provide you with information
about the status of the scanner while you are using it.
A menu-driven user interface provides access to the
settings that control what the scanner monitors.
Below are examples of the scanners menu.
-MainMenu-
Scan >
Scanlists
Set Location
Browse Library
Browse Objects
A “Scan” display shows a scrolling list of enabled
Scanlists while scanning, and displays attenuator and
trunking control channel status. Below provides an
example of the Scanning display.
Scan gg GP
Fire
County Police
Sheriff
City Police
State Police
2015-11-10
9:56:03
®
Individual Object displays are shown when the scanner
is monitoring activity on an enabled Object. The
LCD includes a row of icons at the top that provides
information about the status of the scanner while
monitoring an Object. The amount of information
displayed is configured using the Simple Display option
in the Settings menu. For example, with Simple Display
set to “on”, the following data is displayed for trunking
talkgroups:
¢ Icons
¢ Scanlist
° Object type and “psDr” status
¢ Trunking system
¢ Scanlist
Below is an example of an individual Object display
with Simple Display set to “on”.
sull Gc > County
Police Group: psDR
Police North
Public Safety
Display showing reception of a trunking talkgroup with
Simple Display set to “on”. With Simple Display set to
“off”, additional data is displayed on the screen. The
amount and type of data displayed can be customized
using the Show options in the Settings menu. For
example, below is the same Object displayed with
Simple Display set to “off” and Show Radio ID set to
“ ”,
on”:
¢ Icons
¢ Scanlist
¢ Object type and “psDr” status
° Object name
¢ Trunking system
© Radio ID
19
Untitled-1 19 2015-11-10 9:56:03
sill Gc
County Police
TGRP psDR
Police North
Public Safety
Radio ID: 18249
Display showing reception of a trunking talkgroup with
Simple Display set to “on” and Show Radio ID enabled.
There are many combinations of data that can be shown
on the Object display using the Show options in the
Settings menu. You can learn more about these options
in the Settings Menu section of the guide.
“osDr” Indicators
In the Individual Object displays there are four
characters on the right hand side of the display that
indicate the status of priority, skip/lockout, delay
® and recording for the selected or active object. The ®
following indicators are possible:
P= priority off, P= priority on
s= skip off, S= skip on, L=lockout on
d= delay off, D=delay on
r= recording off, R=recording on
20
Untitled-1 20 2015-11-10 9:56:03
Untitled-1 21
®
Display Icons
A row of icons at the top of the display provides status
information about the scanner. These icons are defined
as follows:
S Squelch circuit (or “gate”) is open
G When present, the attenuator is set for Global
mode
A When present, the attenuator is active
GA When present, Global attenuator is on, and the
attenuator is active
AM AM mode is active
FM FM mode is active
NE Narrow FM mode is active
DG The radio is receiving P25 digital audio with AGC
Dg The radio is receiving P25 digital audio without
AGC
D2 The radio is receiving P25 Phase II digital audio,
with or without AGC
Fn Function key is active
> Scan mode (scanning)
[J Pause mode (monitoring a single Object)
@ Being recorded on the active or selected Object
@ Recording is enabled but recording is suspended.
The SD card is almost out of space.
all Signal meter indicating strength
Currently receiving trunking control channel data
Encrypted digital traffic detected
IF The radio's IF (discriminator) output mode
is active.
P/p Priority On/Priority Off
S/s Skip On/Skip Off
D/d Delay On/Delay Off
L/- Lock Out On/Lock Out Off
GE: Battery status Indicator
# External power connected
21
®
2015-11-10
9:56:03
Untitled-1 22
®
EZ Scan Library
Your scanner comes with an installed Micro SD card
that contains the entire USA/Canadian Radio Reference
database as well as the EZ Scan software.
NOTE: Make a copy of the EZ Scan software files in
case the SD card is lost or damaged.
To remove the Micro SD card from the scanner:
WARNING: To prevent corrupted data on the Micro SD
Card, always turn the scanner off using the front panel
power key before opening the battery compartment
cover.
1. Turn off scanner, unplug external power, and remove
the batteries.
2. Press and release the Micro SD card.
3. To reinsert the Micro SD card, with the label facing
the front of the radio press it in until it clicks in place.
NOTE: Always use the EZ Scan software “Prepare
Scanner Memory/SD Card For Use” option under the
“Scanner/ SD Card"menu to format the Micro SD
Card if the card is not performing as expected or if the
scanner does not power up with the Micro SD Card.
The Micro SD card comes formatted for the standard
FAT file system with a cluster size of 32k.
To format additional cards (2GB or smaller), use only
the EZ Scan software to format the Micro SD card.
¢ Format using the FAT file system with 32k clusters.
e If you use Micro SD cards larger than 2GB, format
using FAT32 with 32k clusters.
¢ Formatting the Micro SD card for other file system
types may cause EZ Scan to malfunction.
Connecting the scanner to a computer with the
supplied USB cable allows you to access the card with
the EZ Scan software and update the Library, edit the
configuration and stored objects, optimize the card, and
reformat the card if necessary. You can also connect the
SD Card to an external reader, which may provide faster
data transfer rates when compared to accessing the
card while it is in the radio.
22
2015-11-10
9:56:03
Untitled-1 23
®
For reference, below is the directory structure for the
Micro SD Card. You may wish to make a copy of the
CDAT folder on your computer as a backup. The CDAT
folder contains your EZ Scan programming. Modifying
these directories or their contents outside of the
scanner or the EZ Scan software is not recommended,
and may cause the scanner to malfunction.
BTMP Contains various temporary files used by the
scanner
CDAT Contains your programming
CDAT_VS.nnn Contains programming for V-Scanner
folder number nnn,where nnn may range from 001 to
200
DB Contains the Library
MTMP Contains various temporary files used by the
scanner
STMP Contains various temporary files used by the
scanner
CURVS.DAT Configuration information CONFIG.BIN
Configuration information REC Audio recordings
SOFTWARE EZ Scan Software
WARNING: Modifying these files, directories or
contents of directories is not recommended, and may
cause the scanner to malfunction, and may result in loss
of programming data.
Maximum Card Size
You can purchase additional cards to store different
configurations or backups for your EZ Scan data. Up to
a 32GB SD card may be used. We recommend SanDisk
Micro SD cards
23
2015-11-10
9:56:04
| e |
Installing EZ Scan Software
A method for programming a new scanner is using the
supplied USB cable and the included software. Also
www.RadioReference.com provides a range of resources
to help improve your overall scanning experience.
EZ Scan easy-to-use software helps you:
¢ Make changes to EZ Scan’s programming and
configuration
¢ Update the Library to the most current version
e Update EZ Scan’s firmware for enhancements and
bug fixes
© Format and maintain the Micro SD card
To install, connect the scanner to your computer's USB
port. Using windows explorer, open the SD Card to
view files, select software, then select setup.exe and
follow the on-screen instructions.
Accept all prompts when asked. User's can also insert
the SD Card into your computer via a card reader,
open the SD Card, find and open the "Software" folder
and click on "setup.exe", then follow the on-screen
instructions.
You can import, configure, and update the librar
@ directly with your scanner or with the EZ Scan software. @
Library Updates
Your EZ Scan comes with the most current library data
available from www.RadioReference.com. However, you
can use the EZ Scan Software to check for updates to
the library data.
NOTE: Updating the Radio Reference library requires
an internet connection.
To check for library updates:
1. Select Check for Library Update in the update menu.
Select Check for Updates to start.
2. If updates are available, click Download Updates.
3. When the update is complete, click Done.
24
Untitled-1 24 2015-11-10 9:56:04
Preferred Programming - from
Library
1. From the Main Menu, select Browse Library.
. Select country.
. Select first letter of State/Province.
. Select Counties/Cites.
2
3
4. Select State/Province.
5
6. Select first letter of County.
7
. Select County.
8. Select Data Type NOTE: Police/Fire and Emergency
services will be in “Categories” for smaller towns,
“Systems” for larger ones.
9. Select desired agency, category or system available
for the county.
10. Select desired subcategory. Investigate listings by
pressing P® to go deeper into that selection. When the
cursor switches from the right side of the screen to the
left, you are at the bottom of a category. NOTE: When
selecting a System, check at least one of the “Sites”
within your range, then go further into Categories to
® find objects. ®
11. Use the SEL button to check boxes for services
you wish to monitor. Press SEL to un-check a selected
service and at anytime press < to go back. Once all
desired objects have been checked, press MENU.
12. Select Import Selected.
13. Select desired scanlist location for selected objects
and press to save. Note that Scanlist 001 is already
selected, so no need to select another scanlist the first
time. For the next scanlist, uncheck the first scanlist and
check the box for the desired scanlist, otherwise, you
will be adding every object to the first scanlist.
14. Press SEL to continue to main menu.
15. Select Scanlists from main menu. Use the
A/V/<4/> to rename the scanlist if desired. Confirm
box beside desired scanlist is checked.
16. Repeat steps to add additional scanlists, or select
Scan from the Main Menu to begin scanning.
17. Once you are happy with your programming, Use
the EZ Scan PC application to save data from the
scanner. Of course you can use any combination of
programming from the Scanner Keyboard or the PC
app, just keep track of which has the most updated list.
NOTE: When traveling or for quick programming, refer to
location based, ZIP code programming.
25
®
Untitled-1 25 2015-11-10 9:56:04
| e |
Backup into the first V-Scanner folder
PC Objects can be backed up to the first available
V-Scanner folder from the Set Location menu (See
V-Scanner II section for a discussion of Folders).
We recommend you back up your data to guard against
accidental changes or deletions.
From the Set Location menu scroll to Backup Data and
press the P key.
-Set Location-
By City
By County
By ZIP Code
Backup Data
Clear Channels
Press the P/II/SEL key to back up your data, or press
the SKIP key to return to the Set Location menu without
backing up.
& -Confirmation- &
Really backup to first available VScanner folder?
SEL=Yes, SKIP=No
Updating the Library (EZ Scan)
To update the EZ Scan library:
In the Main Menu, select Update from Lib and press P.
The scanner asks if you want to use new Alpha Tag
(names) from the library.
Press SEL for yes or SKIP for no.
NOTE: Unit must be connected to an external power
source.
26
Untitled-1 26 2015-11-10 9:56:04
Untitled-1 27
®
Library Structure
Each State contains three data types:
e Agencies — Statewide conventional frequencies
* Counties/Cities — County or independent city
e Systems — Statewide Trunked systems, control
frequencies (sites) and talkgroups.
Each County contains three data types:
e Agencies — Local conventional frequencies
* Categories — Public Service conventional frequencies
e Systems — Public Service Trunked systems, control
frequencies (sites) and talkgroups.
NOTE: Not all states have a statewide trunked radio
system.
WARNING: Modifying these directories or their
contents is not recommended and may cause EZ Scan
to malfunction.
EZ Scan Library Notes
eA "D" indicates that the item uses an unsupported
digital modulation and cannot be monitored.
¢ An “S” indicates a trunked system that is not
supported by the scanner.
A gray box (LB) indicates that some frequencies in a
grouping are selected, but not all.
Manual Programming - Enter
Conventional Frequency
1. Press MENU to access Main Menu.
2. Scroll to and select “Program Menu” then “Add
Conv Freq”.
3. Simply write over the existing frequency or press
“SKIP” to clear. Using the alphanumeric keypad
(WS1088) or the AV, <P buttons, enter the desired
conventional frequency. Press SEL when finished.
4. Scroll to “Save Changes” then press SEL.
5. Press MENU returns to Main menu.
27
2015-11-10
9:56:05
Untitled-1 28
®
Standard Text Entry Method
Your scanner features a high-contrast, backlit
alphanumeric display that provides constant feedback
about what the radio is doing while scanning and
monitoring your “Scannable Objects”. To get the most
out of your scanner and this display, you will want to
name your objects as you program them into the radio.
This allows for easy identification of active objects while
the radio is scanning, and makes it easier than ever to
find objects that you wish to monitor, edit or delete
using the powerful FIND feature.
Your scanner uses a simple text entry method that
allows entry of all uppercase and lowercase letters of
the alphabet, numbers, and punctuation symbols.
Entering and Editing Alphanumeric Information
(WS1088) A Standard Text Entry Method is used for
entering alphanumeric information into the radio.
This method allows easy access to each letter in the
alphabet by pressing two keys that represent the letter.
Take a moment to study the numeric keys on the
keypad and you will notice that keys 2-9 each have
three or four letters silk screened on the front panel just
above each key. To enter a letter in an alphanumeric
text field, simply press the number key below the letter
you wish to type first, then press the number key that
corresponds with the position of the letter in the silk
screen group. For example, the number 2 is used to
access the letters A, B and C. To type the letter A,
press 2 to select the ABC group, then 1 to select the
irst letter in the group, A. Likewise, to type the letter B,
press 2 to select the ABC group, then press 2 again to
select the second letter in the group. And, to type the
letter C, simply press 2, then 3 to select the third letter
in the “ABC” group.
To enter numbers in alphanumeric text fields, press 1
first, then the number you wish to type.
To enter punctuation, press 0 first to see the first
set of punctuation, then press the number key
that corresponds with the position of the desired
punctuation mark in the set.
Press the . (period) key to enter a space.
While using Standard Text Entry, the Fn key serves as a
shift key. For letters, uppercase text is typed by default,
and you can shift to lowercase by pressing the Fn key
before entering a character. For punctuation, the Fn key
accesses a second set of punctuation marks. The shift
action of the Fn key remains active until it is pressed
again.
Use the < keys to move the cursor to the desired
location in edit fields. Press Fn < or Fn ® to move
the cursor to the beginning or end of an edit field,
respectively.
28
®
2015-11-10
9:56:05
®
The cha