Scanners

Manual / Guide · 2011

Uniden HomePatrol Extreme Edition (v2.02) — Owner's Manual

Read the PDF (65 pp) ↗

Guide to the paid HomePatrol Extreme upgrade: activating the registration key, Mass Storage vs Serial USB modes and serial drivers, front-panel programming of conventional and trunked systems, trunked system analyzers, EDACS/LTR LCN finder, band scope, RF power plot, trunking and conventional discovery, limit search, and raw data output. Written for the HomePatrol-1; the HomePatrol-2 Extreme feature set is the same.

Manufacturer
Uniden
System
HomePatrol
Author
Uniden
Year
2011
Type
Manual / Guide
Language
English
Pages
65
Credit
Uniden America Corporation (info.uniden.com)
  • scanner
  • uniden
  • homepatrol
  • extreme upgrade
  • trunking discovery
  • band scope
  • system analyzer
  • owners manual

← Back to the Reference Library

Uniden HomePatrol Extreme Edition (v2.02) — Owner's Manual

Version 2.02 – Extreme Edition © Copyright 2011 Uniden America Corporation. All Rights Reserved. Uniden and HomePatrol are registered trademarks of Uniden America Corporation. Other trademarks used in this document are the property of their respective trademark holders. 1|Page Contents Editing System Options........................................... 44 Introduction ......................................................................3 Creating Sites .......................................................... 45 Activating the Extreme Features.......................................4 Creating a Department ........................................... 47 Installing HomePatrol Sentinel......................................4 Save Found TGIDs ....................................................... 50 Updating your HomePatrol‐1 Firmware........................4 Advanced System Features............................................. 50 Purchase a Registration Key..........................................4 Analysis Features ........................................................ 50 Applying the Registration Key to your HomePatrol‐1...4 Trunked System Analyzer ....................................... 51 Connecting to a PC After the Upgrade..............................5 EDACS / LTR LCN Finder.......................................... 53 Installing Serial Drivers..................................................5 Band Scope ............................................................. 55 Programming Radio Systems ............................................6 RF Power Plot.......................................................... 57 General Programming Steps .........................................6 Raw Data Output ........................................................ 57 Programming a Conventional System ...........................6 Discovery Features ......................................................... 58 Creating a Department..............................................7 Trunking Discovery Mode........................................... 58 Programming P25 Standard Trunked..........................10 Conventional Discovery Mode.................................... 60 Editing System Options ...........................................11 Review Discovery Mode ............................................. 61 Creating Sites...........................................................12 Reviewing a Trunking Discovery Session ................ 61 Creating a Department............................................14 Reviewing a Conventional Discovery Session......... 63 Editing Unit IDs........................................................17 Limit Search ................................................................ 64 Programming P25 One‐Frequency Trunked................19 Keeping things Updated ................................................. 65 Editing System Options ...........................................20 Creating Sites...........................................................20 Creating a Department............................................23 Editing Unit IDs........................................................25 Programming Motorola Trunked ................................27 Editing System Options ...........................................28 Creating Sites...........................................................28 Creating a Department............................................31 Editing Unit IDs........................................................34 Programming EDACS Trunked.....................................35 Editing System Options ...........................................36 Creating Sites...........................................................37 Creating a Department............................................39 Editing Unit IDs........................................................42 Programming LTR Trunked..........................................43 2|Page newly discovered channels for later review and Introduction identification.  Limit Search – searches a range of frequencies The HomePatrol‐1 v2 Extreme Edition firmware for activity. introduces features never before found in a consumer communications receiver. Targeted to the advanced user,  Raw Data Output – outputs raw binary data it turns your HomePatrol‐1 into a tool suitable for based on the received signal and data slicing discovering new channels, analyzing known systems, and parameters you set. complete flexibility in the field.  USB Audio Output and Control – allows you to capture or stream audio and control the In order to use the Extreme Edition features, you need to HomePatrol‐1 using a single USB connection. apply a registration key, available for purchase at Read on to discover how to use these new features. www.Uniden.com. This key unlocks the following Extreme features:  Complete field programmability – edit existing systems or create new ones using the HomePatrol‐1’s touch‐screen interface. New channel settings include: o Per‐Channel Delay o Channel Alerts o Volume Offset o Service Type  Trunked System Analyzers – let you view and review trunked system status and activity. Includes separate sections for: o System Load / Reception Status o Current Activity Chart o LCN Activity Monitor o Activity Log o Talk Group Converter  EDACS / LTR LCN Finder – analyzes system traffic to determine the LCN assignments for EDACS and LTR systems.  Band Scope – Graphically indicates the received signal level across a range of frequencies to help identify RF signal sources.  RF Power Plot – Graphically indicates the received signal level for a single frequency over time to help locate RF signal sources and to determine the effect of other factors on received signal strength.  Trunking Discovery – monitors system traffic on a trunked radio system to find unknown channels. Automatically records audio from and logs newly discovered channels for later review and identification.  Conventional Discovery – searches a range of frequencies to find unknown signals (signals on frequencies not already know to be in use in your area). Automatically records audio from and logs 3|Page Purchase a Registration Key Activating the Extreme Features A registration key can be purchased through Uniden.com. Before using the Extreme Features: Check http://info.uniden.com/HomePatrol for purchase details.  Install the latest version of HomePatrol Sentinel Software on your PC Applying the Registration Key to your  Update the firmware in your HomePatrol‐1 to HomePatrol‐1 the latest version When you complete the purchase, you will be provided  Purchase a Registration Key with a 32‐digit key that is specific to your HomePatrol‐1.  Apply the registration key to your HomePatrol‐1 This key is only valid for the HomePatrol‐1 having the serial number you specified during purchase. Follow Installing HomePatrol Sentinel these steps to apply the key: Download the latest version of HomePatrol Sentinel from 1. Turn on the HomePatrol‐1. http://info.uniden.com/HomePatrol. Unzip the 2. Select MENU  Advanced Menu  Advanced downloaded file, run Setup.exe and follow the on‐screen Option  Register Advanced prompts to complete installation. You do not need to 3. Key in the registration key and select ACCEPT. remove any previous version, first. This unlocks all Extreme features. Updating your HomePatrol‐1 Firmware Follow these steps to update your HomePatrol‐1’s firmware to the latest version: 1. Plug in the HomePatrol‐1’s AC adapter or ensure that the HomePatrol‐1 has fully charged batteries installed 2. Connect your HomePatrol‐1 to the PC using the supplied USB cable, then turn on the HomePatrol‐1. If prompted, select “Mass Storage Mode” on the HomePatrol‐1. The HomePatrol‐1’s screen will blank white. 3. Start Sentinel on your PC. Note: The PC must be connected to the Internet for the following steps. 4. In Sentinel, select UPDATE  Update Firmware… Sentinel checks the web for the latest firmware and writes it to your HomePatrol‐1. 5. When Sentinel completes writing to your HomePatrol‐1, disconnect the USB cable. The HomePatrol‐1 then applies the update and reboots. 4|Page Connecting to a PC After the Installing Serial Drivers Upgrade Before you use the Serial mode for the first time, you must install the serial drivers on your PC. After upgrading to the extreme features, your HomePatrol‐1 will prompt you to select Mass Storage or For Windows XP or Windows Vista, copy the appropriate Serial mode when you connect to a PC. driver from your HomePatrol’s “USB Driver” directory to a folder on your hard drive (if this directory is not on your The serial mode will be used for audio streaming, raw HomePatrol‐1, you can download the files from data output, and serial control modes. Upon release, http://info.uniden.com/HomeePatrol). software to use these functions is not available, however the protocols have been provided to 3rd‐party software When you select the serial mode, your computer will ask authors for development. you for the location of the drivers. You use Mass Storage mode for database updates, For Windows XP, select Hp1WinXPCom.inf. firmware updates, and general connection to the For Windows Vista, select HP1WinVista7Com.inf. HomePatrol Sentinel software. After the update, the following display appears when you use Mass Storage For Windows 7, copy the Hp1WinVista7Com.inf file to mode. the c:/windows/inf directory. When you select serial mode for the first time, Windows will find and install the driver. When using serial mode, your HomePatrol‐1 is assigned a com port number. The assigned com port can differ, depending on which USB port you have connected the USB cable to. 5|Page Then, select Advanced Option and Edit Favorites Lists. Programming Radio Systems The Extreme edition allows you to edit or create radio systems in a Favorites List. This section outlines the steps to program systems. General Programming Steps To program a system (or edit an existing system) you follow these basic steps: 1. Create a Favorites List and add the system to edit to that Favorites List (for an existing system). We recommend you use Sentinel to perform this step. 2. Edit the Favorites List using the Advanced Options. 3. Select the system to edit, or create a new system. Since editing an existing system is straightforward once Select the Favorites List for the system you want to you learn to create a new system, this manual covers program (or create a new list). only programming new systems. In the following sections, we assume you have created a Favorites List called “My Systems” and are adding the systems to that list. The instructions can be repeated to add additional elements to a system. For example, to create a second department on a system, or an additional channel for a department, simply repeat the steps provided in the next sections. Select Create New System (or select the system you want Programming a Conventional System to edit). From the Main Menu, select Advanced Menu. Select Conventional. 6|Page Name the system. Creating a Department From the system menu, select Edit Department. Confirm that you want to create the Conventional System. Create a Department to contain channels. The HomePatrol‐1 now provides a menu for system settings. Name the Department. Edit Name – Allows you to change the name of the system The HomePatrol‐1 presents a menu for Department settings. Edit Department – Lets you create or edit departments to hold channels for the system. Copy System – Copies the entire system. This is useful if you want to make a similar system later. Delete System – Deletes the system from the Favorites List. Edit Name – Lets you change the Department’s name. Edit Channel – Allows you to edit or add channels for the Department. Set Location – Lets you set the geographic boundaries for the department. This is used for location‐based channel selection. 7|Page Delete Department – Lets you delete the department. Set the frequency for the Channel. Editing Channels Select Edit Channels from the Department menu. You will now see the Channel menu. Create a new channel. Name the Channel. Edit Name – Allows you to rename the channel. Edit Frequency – Allows you to change the channel’s frequency. Set Audio Type – Lets you set the channel to use Analog, Select a Service Type for the Channel. Digital, or both. If you know the type of transmission being used on the channel, setting a specific value can improve performance. Modulation: AUTO – Lets you change the modulation method used for the channel. The default of AUTO will cause the HomePatrol‐1 to use the modulation typically used for the frequency band. You can tap this control to set a different modulation type: NFM, FM, or AM. Attenuator: OFF – Lets you turn on/off attenuation for the channel. Delay: 2 sec – Lets you set the channel delay (the amount of time the HomePatrol‐1 stays on a frequency after a transmission ends before continuing scanning.  2, 5, 10, or 30 seconds – HomePatrol‐1 waits the specified amount of time. 8|Page  0 Seconds – HomePatrol‐1 resumes scanning as Then, select whether you will use a circle or rectangle(s) soon as a transmission ends. to define the department’s location.  ‐10, ‐5 seconds – Forces scan resume after the set duration, even if the transmission continues. Set Alert – Lets you set an alert tone that will sound whenever the channel becomes active. Volume Offset – Allows you to set a volume offset for the channel that will either reduce (negative values) or increase the channel’s volume relative to other channels. Set Service Type – Lets you change the service type If you select Circle, tap the existing coordinates. assignment for the channel. Copy Channel – Puts the channel information into the copy buffer. This can be used to quickly copy channel settings for an additional channel (after you Copy a channel, a menu option appears to Paste Channel at the add channel menu). Move Channel – lets you move a channel to a different department (more than one department must exist in the system for this option to operate). Then, use the form to enter the latitude and longitude of Delete Channel – deletes the current channel from the the circle’s center. Department. Setting a Department’s Location You can define a departments location using either a single circle (defined by the centerpoint’s latitude and longitude and the distance from the center, or range) or by using rectangles (each rectangle defined by the latitude and longitude of opposing corners). Note, the format used to enter the location is set by the At the Department Menu, select Set Location button in the lower right corner of the screen. In this example, we show coordinates using DMS format. Select NEXT, then enter the range for the department (the distance from the center of the circle to an edge). ACCEPT the range to store the setting. 9|Page If you select Rectangles, tap Create New Location to add a rectangle, or an existing rectangle to edit it. Programming P25 Standard Trunked Note: You would also use this system type for P25 X2 TDMA systems. However, you will not be able to monitor channels operating using TDMA. From the Main Menu, select Advanced Menu. Enter the latitude and longitude for one corner of the rectangle. Then, select Advanced Option and Edit Favorites Lists. Next, enter the latitude and longitude for an opposing corner of the rectangle. When you accept the setting, you are returned to the location selection screen with the new settings added. Select the Favorites List for the system you want to program (or create a new list). Repeat this to define rectangles for the department. The HomePatrol‐1 will use either the Circle or Rectangles, depending on which one you last selected. 10 | P a g e Select Create New System (or select the system you want to edit). Edit Name – Allows you to change the name of the system Select P25 Standard Trunk. Edit System Options – Lets you set the system level option(s). Edit Site – Lets you add/edit sites. Edit Department – Lets you create or edit departments to hold system channels. Edit Unit IDs – Allows you to enter and edit Unit IDs so that individual radios are identified on the system. Copy System – Copies the entire system. This is useful if Name the system. you want to make a similar system later. Delete System – Deletes the system from the Favorites List. Editing System Options For P25 Trunked systems, the only system‐level option is the ID Search option. Confirm that you want to create the P25 Trunk System. Tap the selection to toggle between ID Search On (HomePatrol‐1 will stop on all unavoided channels, even if not in its database) and ID Search Off (HomePatrol‐1 The HomePatrol‐1 now provides a menu for system ignores all channels not in its database). settings. 11 | P a g e Attenuator: Off – Allows you to attenuate signals when Creating Sites receiving the site, if set to On. Sites contain the radio frequency information used by Set Location – Lets you enter the site’s geographic trunked radio systems. To create a site for the system, location. select Edit Site from the system’s menu. Delete Site – Allows you to delete the site from the database. Editing the Band Plan Note: Most P25 trunked systems automatically receive the band plan from the control channel. On these systems, you do not need to enter a band plan. If you do enter a band plan for such a system, it will be overwritten by the band plan information provided on the control Then, select Create New Site. channel. To set the band plan, select Edit Band Plan from the Site menu. Enter a name for the site. Then, select the table entry to edit. You will then see the site menu. Enter the upper frequency for the table entry. Then click next. Edit Name – Lets you change the Site’s name. Edit Band Plan – Lets you enter or edit the site’s band plan. Edit Frequency – Lets you add or change the frequencies used by the site. 12 | P a g e Enter the frequency spacing for the band plan entry. The Frequency menu appears. Then click Accept. Edit Frequency – allows you to change the frequency. Repeat this for additional table entries. Delete Frequency – deletes the frequency from the site. Entering Site Frequencies New Frequency – tap to add additional frequencies, then repeat the above steps. To enter frequencies for the site, select Edit Frequency from the Site menu. Setting a Site’s Location You can define a site’s location using either a single circle (defined by the centerpoint’s latitude and longitude and the distance from the center, or range) or by using rectangles (each rectangle defined by the latitude and longitude of opposing corners). At the Site Menu, select Set Location. Then, select Create New Frequency. Then, select whether you will use a circle or rectangle(s) to define the site’s location. Enter the frequency and tap Accept. 13 | P a g e If you select Circle, tap the existing coordinates. Enter the latitude and longitude for one corner of the rectangle. Then, use the form to enter the latitude and longitude of the circle’s center. Next, enter the latitude and longitude for an opposing corner of the rectangle. Note, the format used to enter the location is set by the button in the lower right corner of the screen. In this When you accept the setting, you are returned to the example, we show coordinates using DMS format. location selection screen with the new settings added. Select NEXT, then enter the range for the department (the distance from the center of the circle to an edge). Repeat this to define rectangles for the site. The HomePatrol‐1 will use either the Circle or Rectangles, ACCEPT the range to store the setting. depending on which one you last selected. If you select Rectangles, tap Create New Location to add a rectangle, or an existing rectangle to edit it. Creating a Department From the system menu, select Edit Department. 14 | P a g e Create a Department to contain channels. Editing Channels Select Edit Channels from the Department menu. Name the Department. Create a new channel. The HomePatrol‐1 presents a menu for Department settings. Name the Channel. Edit Name – Lets you change the Department’s name. Edit Channel – Allows you to edit or add channels for the Select a Service Type for the Channel. Department. Set Location – Lets you set the geographic boundaries for the department. This is used for location‐based channel selection. Delete Department – Lets you delete the department. 15 | P a g e Set the Talk Group ID for the Channel. Volume Offset – Allows you to set a volume offset for the channel that will either reduce (negative values) or increase the channel’s volume relative to other channels. Set Service Type – Lets you change the service type assignment for the channel. Copy Channel – Puts the channel information into the copy buffer. This can be used to quickly copy channel settings for an additional channel (after you Copy a channel, a menu option appears to Paste Channel at the Note: To enter the I‐Call Wildcard, enter i0 as the Talk add channel menu). Group ID. Move Channel – lets you move a channel to a different You will now see the Channel menu. department (more than one department must exist in the system for this option to operate). Delete Channel – deletes the current channel from the Department. Setting a Department’s Location You can define a departments location using either a single circle (defined by the centerpoint’s latitude and longitude and the distance from the center, or range) or by using rectangles (each rectangle defined by the latitude and longitude of opposing corners). At the Department Menu, select Set Location. Edit Name – Allows you to rename the channel. Edit Talk Group ID – Allows you to change the channel’s Talk Group ID. Delay: 2 sec – Lets you set the channel delay (the amount Then, select whether you will use a circle or rectangle(s) of time the HomePatrol‐1 stays on a frequency after a to define the department’s location. transmission ends before continuing scanning.  2, 5, 10, or 30 seconds – HomePatrol‐1 waits the specified amount of time.  0 Seconds – HomePatrol‐1 resumes scanning as soon as a transmission ends.  ‐10, ‐5 seconds – Forces scan resume after the set duration, even if the transmission continues. Set Alert – Lets you set an alert tone that will sound whenever the channel becomes active. 16 | P a g e If you select Circle, tap the existing coordinates. Enter the latitude and longitude for one corner of the rectangle. Then, use the form to enter the latitude and longitude of the circle’s center. Next, enter the latitude and longitude for an opposing corner of the rectangle. Note, the format used to enter the location is set by the button in the lower right corner of the screen. In this When you accept the setting, you are returned to the example, we show coordinates using DMS format. location selection screen with the new settings added. Select NEXT, then enter the range for the department (the distance from the center of the circle to an edge). Repeat this to define rectangles for the department. The HomePatrol‐1 will use either the Circle or Rectangles, ACCEPT the range to store the setting. depending on which one you last selected. If you select Rectangles, tap Create New Location to add a rectangle, or an existing rectangle to edit it. Editing Unit IDs Unit IDs identify the specific radio currently transmitting on the channel. You can program Unit IDs into the HomePatrol‐1 so that it will display user information during scanning. You will also need to turn on the Unit ID Display option (MENUDisplay Options). 17 | P a g e From the System menu, select Edit Unit IDs. Edit Name – lets you change the alpha tag assigned to the ID. Edit Unit ID – lets you change the Unit ID. Set Alert – lets you set an alert tone that sounds whenever the user transmits. Copy ID – lets you copy the ID information so that you can Paste it into another location. Delete ID – lets you delete the ID information from the Select Create a New Unit ID. HomePatrol‐1. Assign an alpha tag to the ID, then tap Next. Input the Unit ID, then tap Accept. You will now see the Unit ID menu. 18 | P a g e Select Create New System (or select the system you want Programming P25 One‐Frequency to edit). Trunked From the Main Menu, select Advanced Menu. Select P25 One Freq Trunk. Then, select Advanced Option and Edit Favorites Lists. Name the system. Confirm that you want to create the P25 Trunk System. Select the Favorites List for the system you want to program (or create a new list). 19 | P a g e The HomePatrol‐1 now provides a menu for system Tap P25 NAC Option for the P25 NAC menu. settings. Tap NAC Search to have the HomePatrol‐1 automatically Edit Name – Allows you to change the name of the determine and display the NAC for transmission. system Or, tap Set P25 NAC to set a specific NAC that must be Edit System Options – Lets you set the system level present for the HomePatrol‐1 to stop on transmissions option(s). on the system frequency. Edit Site – Lets you add/edit sites. Creating Sites Edit Department – Lets you create or edit departments to Sites contain the radio frequency information used by hold system channels. trunked radio systems. To create a site for the system, Edit Unit IDs – Allows you to enter and edit Unit IDs so select Edit Site from the system’s menu. that individual radios are identified on the system. Copy System – Copies the entire system. This is useful if you want to make a similar system later. Del