Scanners

Firmware · 2024-01

Uniden SDS200 firmware 1.03.03 sub (Motorola Type II test)

Verified — manufacturer file

Download zip (123 KB) Manufacturer's page ↗

Test sub firmware 1.03.03, issued by Uniden in January 2024 while investigating poor Motorola Type II reception after the Waterfall release. Per Uniden's readme it changes the 4FSK filter to a least-squares method. Superseded by public sub 1.03.05 (19 January 2024).

Read before installing. TEST BUILD - superseded. Not compatible with main 1.21.00 or older. Sentinel cannot overwrite it (its number is higher than the version on Uniden's server); return to sub 1.03.02 with the included file by the same manual method. Uniden has since hidden the link on its change-log page; the file is still served.
Product
SDS200 firmware
Version
1.03.03 sub (Motorola Type II test)
Released
2024-01
Runs on
Any PC that can copy files to a USB mass-storage device (Uniden's steps use Windows Explorer)
Applies to
Uniden SDS200
Zip SHA-256
0ed4d990bd830803d078f95232ca9107055b98ec3be81eed73d18378a057e4e5

Contents

FileSizeSHA-256
SDS200 Motorola Type2 test Sub V1.03.03.zip120 KB22f196221d367622636795afb77f09d7fecc13205626cb08053a0f6c87eb913f
README.txtThese instructions
SHA256SUMSChecksums of the files above

Instructions

The complete README.txt included in the zip:

Uniden SDS200 firmware 1.03.03 sub (Motorola Type II test)
==========================================================

WHAT THIS IS
Test sub firmware 1.03.03, issued by Uniden in January 2024 while
investigating poor Motorola Type II reception after the Waterfall release. Per
Uniden's readme it changes the 4FSK filter to a least-squares method.
Superseded by public sub 1.03.05 (19 January 2024).

IMPORTANT: TEST BUILD - superseded. Not compatible with main 1.21.00 or older.
Sentinel cannot overwrite it (its number is higher than the version on
Uniden's server); return to sub 1.03.02 with the included file by the same
manual method. Uniden has since hidden the link on its change-log page; the
file is still served.

This is a TEST build that Uniden distributed during a fault investigation. It
is kept for the record; a scanner should run the current public release.

APPLIES TO
The Uniden SDS200 (US model) only. Every firmware file carries the model name
(SDS200_...). Do not use it on the SDS100, SDS150, BCD436HP or BCD536HP. The
European SDS200E uses separately named firmware files (e.g.
SDS200E_V1_23_09.bin, per RadioReference owners) and must not be given these
files.

BEFORE STARTING
  - A Windows PC. Uniden's instructions use Windows Explorer; the scanner
    appears as an ordinary removable disk.
  - The supplied USB cable, in the mini-USB port on the scanner's front panel.
  - The SDS200's power supply connected for the whole update. (Some of
    Uniden's SDS200 readmes say "make sure the battery is fully charged"; the
    SDS200 has no battery, so this is carried over from the SDS100 text.)
  - A backup: copy the whole microSD card to the PC and save the Favorites
    Lists in Sentinel first (Uniden's readme asks for both).
  - Main firmware newer than 1.21.00 (Uniden: the test sub is not compatible
    with main 1.21.00 or older).

CONTENTS OF THIS ZIP
The download zip holds the vendor file exactly as Uniden published it, plus
this README.txt and SHA256SUMS.

  SDS200 Motorola Type2 test Sub V1.03.03.zip  (122663 bytes)
    SHA-256 22f196221d367622636795afb77f09d7fecc13205626cb08053a0f6c87eb913f

  Inside SDS200 Motorola Type2 test Sub V1.03.03.zip:
    Readme SDS200 Sub Motorola type 2 test V1_03_03.txt
      Uniden's own instructions
      2715 bytes
      SHA-256 759e901436ebf2a34819150b149f99bca47aefd91c65ac2d23c9fb96fea7fb10
    SDS200-SUB_V1_03_02.firm
      public sub-processor firmware 1.03.02, for going back
      88816 bytes
      SHA-256 01cc450f9633c33e3c3a99a19c33adac1f570b983431af9304a7fc9a02930dcf
    SDS200-SUB_V1_03_03.firm
      test sub-processor firmware 1.03.03
      88864 bytes
      SHA-256 71fa59340f64d8f742f92c6f34b7b208a7735f66c666fd6a6225d9fa226e273c

INSTALLATION
  1. Turn the scanner on.
  2. Connect it to the PC with the USB cable. The scanner shows "USB Cable
     Detected / Select USB mode" with "Mass Storage = E" and "Serial Port =
     .".
  3. Press E (Yes) to choose Mass Storage. The scanner shows "USB Mass
     Storage".
  4. In Windows Explorer, open the new removable disk, then the "BCDx36HP"
     folder, then its "firmware" folder. It already holds CitiTable_V00_00.dat
     and ZipTable_V00_00.dat - do not touch or delete them.
  5. Unzip the download on the PC and copy the test sub file
     SDS200-SUB_V1_03_03.firm into the "firmware" folder. Only one main (.bin)
     and one sub (.firm) file may be in the folder at a time; with several
     versions present the update will not start or will load incorrectly.
  6. Restart the scanner ("reset the power", in Uniden's words). The update
     starts automatically as it boots. Do not turn the scanner off until the
     update has finished.
  7. When it has finished, the scanner deletes the firmware file(s) from the
     "firmware" folder by itself.

VERIFYING
Menu -> Settings -> See Scanner Information -> Firmware Version shows the main
and sub versions now installed. The firmware file(s) will also have gone from
the card's "firmware" folder.

IF SOMETHING GOES WRONG
  - Update did not start: check that only one main and one sub file are in the
    "firmware" folder and that the file names are exactly as supplied.
  - Scanner will not start properly after files were deleted from the
    "firmware" folder: the two .dat files were probably removed. Uniden's
    remedy is Sentinel -> Clear User Data, which rebuilds the card but erases
    all user data (hence the backup).
  - USB connection fails or is slow: take the microSD card out and use a card
    reader; Sentinel can work on the card directly (see Vol 5 on this site).
    The same folder layout applies.
  - Card errors: back up what is readable, format the card with the SD
    Association's SD Memory Card Formatter (cards up to 32 GB), run Sentinel
    -> Clear User Data, then Update Firmware.
  - Uniden does not document a recovery procedure for an update interrupted by
    power loss; this could not be confirmed from any source. Uniden's readme
    closes with "Please use these files on your risk."

DOWNGRADING
Uniden's readme: Sentinel cannot overwrite this test version because its
number is higher than the version on Uniden's server. To go back, copy the
public files included in this package the same way. A later public release
(sub 1.03.05 or newer, installed by Sentinel) also replaces it.

PROVENANCE
  - Official source:
    https://info.uniden.com/twiki/pub/UnidenMan4/SDS200FirmwareUpdate/SDS200%20Motorola%20Type2%20test%20Sub%20V1.03.03.zip
  - Listed on:
    https://info.uniden.com/twiki/bin/view/UnidenMan4/SDS200FirmwareUpdate
  - Wayback copy: none captured
  - Retrieved: 2026-09-18. Status: verified (downloaded from Uniden's own
    server).

MORE INFORMATION
  - scanners.fubsypoly.com, Uniden SDS200 - Vol 5, Upgrades & Firmware:
    https://scanners.fubsypoly.com/uniden-sds200/vol-5/
  - Reference Library, SDS200 Owner's Manual:
    https://scanners.fubsypoly.com/library/sds200om/
  - Reference Library, Easier to Read SDS100/SDS200 Manual:
    https://scanners.fubsypoly.com/library/easier-to-read-sds100-200-manual/