Scanners

Firmware · 2016-07-29

Uniden BCD436HP/BCD536HP main firmware 1.11.16

Verified — manufacturer file

Download zip (4.1 MB) Manufacturer's page ↗

A package holding firmware 1.11.16 for both the BCD436HP and the BCD536HP, attached to Uniden's firmware page on 29 July 2016, two days after the 1.11.15 release that added DMR support by paid upgrade. 1.11.16 has no entry of its own in Uniden's change log.

Read before installing. Sentinel 1.07.03 or later is required after 1.11.15-series firmware. Superseded by 1.11.20 and later releases.
Product
BCD436HP/BCD536HP combined firmware packages
Version
1.11.16
Released
2016-07-29
Runs on
BCD436HP / BCD536HP (file copied to the microSD card)
Applies to
Uniden BCD536HP / BCD436HP
Zip SHA-256
273d1ca69143a6b5d409c1d49b02b1f8ceaafe534bf421bb879e9c125648a637

Contents

FileSizeSHA-256
BCDx36HP_V1_11_16.zip4.1 MBf2cc92dac3b8be1e38b7d80b5111e500236ed38ba3de76f4eae5ba496409bfff
README.txtThese instructions
SHA256SUMSChecksums of the files above

Instructions

The complete README.txt included in the zip:

Uniden BCD436HP/BCD536HP main firmware 1.11.16
==============================================

WHAT THIS IS
------------
A package holding firmware 1.11.16 for both the BCD436HP and the BCD536HP,
attached to Uniden's firmware page on 29 July 2016, two days after the 1.11.15
release that added DMR support by paid upgrade. 1.11.16 has no entry of its
own in Uniden's change log.

Uniden's change log gives the neighbouring releases. 1.11.15 (27 July 2016):
"Added support for DMR systems by upgrade", fixed a bug with mixed
analog/digital Motorola systems and patches, miscellaneous fixes, and "Must
use Sentinel 1.07.03 or later after this update." 1.11.20 (14 November 2016):
"Adjusted digital filter to improve P25 reception." What 1.11.16 changed
relative to 1.11.15 was not published.

APPLIES TO
----------
The Uniden BCD436HP and BCD536HP. The zip holds one file for each model:
BCD436HP_V1_11_16.bin for the handheld and BCD536HP_V1_11_16.bin for the
base/mobile. Copy only the file that matches the scanner.

BEFORE STARTING
---------------
- BCDx36HP Sentinel 1.07.03 or later on the PC (required after 1.11.15-series
  firmware).
- A backup of the microSD card and Favorites Lists; external power connected.
- DMR reception still needs the paid DMR key; the firmware only makes it
  possible.
- The normal route is Sentinel's UPDATE > Update Firmware, which installs the
  newest release (1.28.24). Use this file only for a deliberate install of
  1.11.16.

CONTENTS OF THIS ZIP
--------------------
- BCDx36HP_V1_11_16.zip (4,326,954 bytes), the unmodified Uniden
  file. SHA-256:
  f2cc92dac3b8be1e38b7d80b5111e500236ed38ba3de76f4eae5ba496409bfff
  It contains:
    BCD536HP_V1_11_16.bin  (2,162,688 bytes, dated 2016-07-29)
    BCD436HP_V1_11_16.bin  (2,162,688 bytes, dated 2016-07-29)
- README.txt, this file.
- SHA256SUMS, SHA-256 checksums of the files in this zip.

INSTALLATION
------------
1. Connect external power and back up the microSD card (copy its whole
   contents to the PC); also save the Favorites Lists in Sentinel.
2. Turn the scanner on and connect it to the PC with the USB cable. The screen
   shows "USB Cable Detected / Select USB mode"; press E to choose Mass
   Storage. The screen then shows "USB Mass Storage".
3. In Windows Explorer, open the removable disk labelled BCDx36HP, then the
   "firmware" folder inside it. It already holds two .dat files
   (CitiTable_V00_00.dat and ZipTable_V00_00.dat). Do not touch them.
4. Copy the one .bin file for this model (BCD436HP_... or BCD536HP_...) into
   the "firmware" folder. Never put two main-firmware files there at the same
   time.
5. Disconnect the USB cable and cycle the power. The update starts on its own.
   Do not turn the scanner off until it finishes.
6. When the update completes the scanner deletes the .bin file from the
   "firmware" folder.

Steps 2 to 6 follow the Readme text Uniden ships inside its 1.28.14 and
1.28.16 downgrade zips, and the scanner step on Uniden's BCD536HP Wi-Fi Test
page ("copy it to the FIRMWARE directory on your scanner. Unplug the USB
cable"). The same steps work with the card in a PC card reader: copy the file
to the card's BCDx36HP\firmware folder, put the card back, and power on.

VERIFYING
---------
On the scanner, go to Menu > Settings > See Scanner Information > Firmware
Version. The screen shows the installed firmware version, the serial number
(ESN) and a checksum. It should read 1.11.16.

IF SOMETHING GOES WRONG
-----------------------
- If the update does not start, check that only one main-firmware .bin file is
  in the "firmware" folder; Uniden's notes say that with more than one file
  the update will not start or will not load correctly.
- If the two .dat files in the "firmware" folder were deleted, the scanner
  will not start properly. Sentinel's Clear User Data restores them but erases
  all user data on the card; restore Favorites Lists afterwards with Scanner >
  Write to Scanner.
- If the card is corrupted, format it with the SD Association's SD Memory Card
  Formatter, run Clear User Data in Sentinel (tick Display all drives), then
  Update Firmware.
- Cutting power while the card is being written can corrupt it. Keep external
  power connected for the whole update.
- Uniden's firmware page warns: "ONLY use Sentinel to upgrade firmware. Some
  users have rendered their scanners non-functional using other update
  methods." A manual file copy is at the user's own risk; Uniden's own
  downgrade notes say it accepts no responsibility for damage.

DOWNGRADING
-----------
On a scanner running a later release, installing 1.11.16 is a downgrade.
Firmware from 1.14.00 onward added NXDN and many DMR fixes, and Sentinel and
database files written by later versions may not match older firmware; this
could not be confirmed either way. Return to current firmware with Sentinel.

PROVENANCE
----------
- File: BCDx36HP_V1_11_16.zip
- Downloaded from:
  https://info.uniden.com/twiki/pub/UnidenMan4/BCD536HPFirmwareUpdate/BCDx36HP_V1_11_16.zip
- Retrieved: 2026-09-18
- Official page:
  https://info.uniden.com/twiki/bin/view/UnidenMan4/BCD536HPFirmwareUpdate
- Status: verified (the file was served by Uniden's own server and is
  byte-for-byte unmodified)

MORE INFORMATION
----------------
- BCD536HP Upgrades & Firmware (vol. 5):
  https://scanners.fubsypoly.com/uniden-bcd536hp/vol-5/
- BCD436HP/BCD536HP Owner's Manual in the Reference Library:
  https://scanners.fubsypoly.com/library/uniden-bcd536hp-owners-manual/
- All BCD536HP documents:
  https://scanners.fubsypoly.com/library?node=scanners/uniden-bcd536hp
- Uniden BCD536HP firmware change log:
  https://info.uniden.com/twiki/bin/view/UnidenMan4/BCD536HPFirmwareUpdate
- Uniden BCD436HP firmware change log:
  https://info.uniden.com/twiki/bin/view/UnidenMan4/BCD436HPFirmwareUpdate

Other versions of BCD436HP/BCD536HP combined firmware packages

← All Uniden BCD536HP / BCD436HP downloads